Initial Operation: Transformer Oil

  1. Fill the tube chamber with oil. Transformer Oil Loading
  2. Check the RF filter assemblies and the tube plate for oil leaks.
    • If leakage is present around the RF filter, repair by tightening the Allen screws around the perimeter.
    • If leakage is present around the "O"-ring seal of the tube face plate and tightening the face plate does not stop the leakage, replace the "O"-ring.


Back to Initial Operation page